Environmental standards and requirements for machine tool installation

To ensure the machine operates accurately and reliably, it is essential to maintain proper environmental conditions around the equipment. Below are detailed guidelines for optimal performance and longevity.

1. Environmental Parameters:

The machine requires a controlled environment to function properly. The following conditions should be maintained:

  • Temperature: Operating range: 17°C – 25°C; Transport range: 0°C – 60°C. Ideal temperature difference should not exceed ±2°C. The ambient temperature should stay within 15°C – 40°C.
  • Humidity: At 20°C, humidity should be between 40% – 70%, with no condensation present.
  • Vibration: Vibration levels must be less than 0.5G to avoid affecting precision.

2. Installation Location:

The machine should not be installed in areas exposed to radiation such as microwaves, ultraviolet light, lasers, or X-rays. Additionally, avoid installing the device in the following locations:

  • Direct sunlight
  • High humidity areas
  • Areas with large temperature fluctuations
  • High vibration zones
  • Strong magnetic fields
  • Dusty environments

Also, avoid the following surroundings near the installation site:

  • Garages
  • Frequently used drive lanes
  • Pressure or stamping machines
  • Welding, spot welding, or argon arc welding areas
  • Substations
  • High voltage power lines
  • Dust-generating equipment or processes

3. Site Preparation:

The foundation where the equipment is installed must be fully compacted, free of voids or loose soil. A stable and reliable power source is required, meeting national standards. Temporary power sources are not allowed. The equipment must have proper grounding protection for safety.

A stable compressed air supply is also necessary. The air must be dry and clean, complying with local regulations. It should be delivered at a pressure of 0.5–0.7 MPa with a flow rate of at least 5 m³/h.

4. Power Supply Requirements:

The installation site must provide a three-phase four-wire power system. The line voltage should be 380V ± 5%. If the site provides 200V ± 5%, no transformer is needed when powering on the device. However, if the voltage is 220V, voltage regulation must be carefully managed to ensure fluctuations do not exceed 220V ± 5%.

5. Compressed Air System:

The main pipeline of the compressed air system should include a filter and a dryer. The air pressure must be maintained at 0.5–0.7 MPa, with a minimum flow rate of 5 m³/h. This ensures consistent performance and prevents damage from moisture or contaminants.

Ordinary Seal